C.6.2 Connections front side BM5030 with safety function
X1
Digital inputs / outputs
BM5030-XX2X-...
Figure 131:
Pin assignment
Pin
No.
Input current per input
Input level
Output current per output
Output level
Connection X1 front side BM5030 with safety function
Assignment
1
Dig. input/output
2
Digital input
3
Digital input
4
Digital input
5
Digital output
6
Digital output
BM5030 with Safety Function
GND 24 V
1)
Inhibit input
BM5030-XXX0
input is high active,
expects 
NO contact
Reserved
Reset
Error
Ready-to-operate
7 mA
High (12 ... 28 V)
500 mA
High (12 ... 28 V)
Instruction handbook b maXX 5000
Document No.: 5.09021.16
X1 Digital inputs/outputs
1:M24V
2: Inhibit input
3: Reserved
4: Reset
5: Error
6: Ready-to-operate
BM5030-XXX1
input is low active,
expects 
NC contact
B
313
of 328