3.3.5.1 Correction values for the output current of the mains inverter BM50XX, BM51XX
Installation
If the devices BM50XX, BM51XX are operated above an absolute altitude of 1000 m,
altitude
then the permitted output current I
duced against the output rated current (see
page 58) according to the following curve.
Figure 18:
Operating
The devices BM50XX, BM51XX were designed to be operated at an operating tempera-
temperature
ture of T
55 °C the permitted output current (I
The coolant temperature complies with the environmental temperature of air-cooled de-
vices, with the water temperature of water-cooled devices and the surface temperature of
the cold plate/mounting panel of devices with cold plate cooling.
The permitted output current I
ing following formula:
Correction value installation altitude k
k
H
120%
1,0
100%
0,8
80%
0,6
60%
0,4
40%
0,2
20%
0%
0m
1.000m
Correction value k
in dependence on the installation altitude H, BM50XX, BM51XX
H
= 40 °C. If the devices are operated at temperatures between 40 °C and
rated
Coolant temperature - 40 °C
k
1
--------------------------------------------------------------------------------- 0,03
=
–
T
permitted
I
permitted
I
=
Output rated current at 40 °C and up to 1000 m,,
rated
see
ZElectrical data BM50XX; BM51XX–
Technical data
(adjusted output rated current) must be re-
permitted
ZElectrical data BM50XX; BM51XX–
2.000m
3.000m
) must be reduced:
permitted
°C
(adjusted output rated current) is calculated accord-
I
k
k
=
T
H
rated
Instruction handbook b maXX 5000
Document No.: 5.09021.16
3
as from
H
4.000m
5.000m
Installation altitude
as from page 58.
of 328
49