11.1.10Connection cable add-on modules
IEE
The connection cable is not offered by Baumüller and must be made by the user:
1 Use the following materials:
2 Connect
Figure 114:
NOTE!
The connection cable must be made according above mentioned instruction, pin as-
signment IEE see
The cable is inoperable with changed assignment of the pins!
m Cable: LiYCY 3 x (2 x 0.14 mm²) + 2 x 0,34 mm² Cu braiding.
m D-sub connector: 9-pin, female (IEE side)
m E.g. D-sub connector: 26-pin, male (b maXX 5000 side)
m Cables must be of twisted pair wire (track -0/0, -A/A, -B/B) from incremental encoder
emulation to further master control systems
m the cable shield with the connector shell of the D-sub male/D-sub female connector
m the 9-pin female connector (IEE side) with the cable
m e.g. the 26-pin D-sub male connector (b maXX 5000 side, pin assignment see
ZConnecting cable for sine/square-wave incremental encoder–
the other cable ending.
Connection cable IEE with b maXX 5000
ZAdd-on modules–
Accessories and spare parts
on page 182!
Instruction handbook b maXX 5000
Document No.: 5.09021.16
11
on page 258) with
259
of 328