3.4
Electrical data
3.4
Electrical data
3.4.1
Electrical data BM50XX; BM51XX
m BM5030 mains rectifier unit without safety function
1)
Input rated power
Input rated current (I
)
eff
Distortion factor of the input current (THD
Input peak current (I
)
eff
DC link voltage, power supply dependent/rated
Internal DC link capacitance (C
DC link discharge time (C
Waiting period between 2 charging processes
(no external DC link capacitance)
Total maximum connectable capacitance in the
DC link
Waiting time between 2 charging processes
with maximum capacitance
Connection power at DC link
Peak power at DC link
Ready-to-operate after
Max. charge-up time
External brake resistor R
External brake resistor continuous power
Quick discharge resistor
Power loss with regard to power supply
Power loss with regard to control voltage
8)
supply
Cooling air requirement power heat sink
Cooling air velocity power heat sink
Cooling air requirement internal space of device
Footnotes refer to
58
Instruction handbook b maXX 5000
Document No.: 5.09021.16
of 328
1) 2) 3)
1)
)
I
1) 2) 3)
)
int
9)
)
int
1) 5)
4) 6)
B
7)
Zpage
65–.
BM5030
-XT0X-.. /-XI0X-.. / -XG0X-..
without charge resistor
6 kVA
8.5 A
57 % ± 10 %
12.5 A for max. 150 s
540 V
at U
DC
Approx. 450 s
internal + external
7.5 kW for max. 150 s
BM5030
-XR0X-.. /-XS0X-.. / -XW0X-..
with charge resistor
14)
6.9 kVA
10.4 A
160 % ± 10 %
15.6 A for max. 150 s
= 3 x 400 V
power supply
470 µF
36 s
7.8 mF
13)
600 s
5 kW
7 s
10 s
33
R
B
5 kW
-
40 W
Max. 10 W
3
40 m
/h
-
3
8 m
/h
Baumüller Nürnberg GmbH