C.6.1 Connection data of BM5030 with safety function
NOTE!
To ensure sufficient current load capacity of the connections, adhere to the specified
torques!
Power supply
BM5030
with
1U1, 1V1, 1W1
safety
Power supply
function
PE
DC link
BM5030
with
1C1 and 1D1
safety
function
X101
BM5030
Connection for
additional DC link
capacitance
function
X200 (SELV/PELV)
24 V power supply
Connection
cross section
Max. 25 mm²
Min. 10 mm²
DC link bar
Connection
cross section
Max. 6 mm²
with
safety
Connection
cross section
Max. 1.5 mm²
(2 wire, 2 pin)
BM5030 with Safety Function
Connection
Torque
method
Screw terminal
Min. 4.0 Nm
Max. 4.5 Nm
Cable lug for M5 Min. 2.2 Nm
Max. 3.0 Nm
Torque
Min. 2.2 Nm
Max. 3.0 Nm
Connection
Torque
method
Plug connector,
spring-clamp
connection
Connection
method
Plug connector,
spring-clamp
connection
Instruction handbook b maXX 5000
Document No.: 5.09021.16
Load capacity
Refer to
ZFuses–
from page 261
-
Max load
capacity of the bar
130 A
Load capacity
-
Max. 41 A
Load capacity
Max. 2.0 A
Plug connector max. 16 A
B
311