4.4
Display and operating elements
4.4.5
Setting the IP address with address switches
®
EtherCAT
CoE
BM5XXX-XXXX-XXXX-01XX
®
EtherCAT
SoE
BM5XXX-XXXX-XXXX-07XX
VARAN
BM5XXX-XXXX-XXXX-02XX
®
POWERLINK
BM5XXX-XXXX-XXXX-04XX
IP-Address
The IP address of the controller consists of 32 bits or 4 bytes (e.g. 192.168.125.203).
S1 to S4
Controller with EtherCAT
address (192.168.) at the factory. Both of the last bytes are set by means of the address
switches S1, S2, S3 and S4. In the process, S1 and S2 as well as S3 and S4 each rep-
resent an 8 bit value.
Controller with POWERLINK
(192.168.100) at the factory. The last byte is set by means of the address switches S3
and S4. In the process, S3 and S4 each represent an 8 bit value.
The IP address 192.168.0.0 or 192.168.100.0 is not permitted/reserved.
For information on changing the base address, refer to the parameter manual.
100
Instruction handbook b maXX 5000
Document No.: 5.09021.16
of 328
®
®
EtherCAT
or VARAN profile:
or VARAN profile: Both of the first bytes are set with the base
®
-profile: The first three bytes are set with the base address
Switch setting up
Switch setting down
®
POWERLINK
profile
Switch setting up
Switch setting down
Baumüller Nürnberg GmbH