10.4.2 Error acknowledgment of BM51XX and BM53XX

If the red error LEDs H14 or H24 light up, at least one error has been detected.
All error messages are reset by error acknowledgment. Individual acknowledgment of er-
rors is not possible. An acknowledgment delete all errors, if deletion was possible on ac-
count of the error cause.
There are three methods of acknowledging an error:
m By means of write access to the control word
m Via a digital input
m Via the pulse enable input:
For further information on the subject of error acknowledgment, see „Parameter manual
b maXX 5000".
Troubleshooting and Fault correction
n BM51XX
The pulse enable input of the BM51XX is linked to an additional option therefore it
is not possible to quit errors via the pulse enable input on the active mains rectifier.
n BM53XX
This is conditional upon the drive only being controlled via the hardware inputs (thus,
the control of the motor is not handled via another communications channel). Fur-
thermore, the option „Error acknowledgment by means of pulse enable" must be ac-
tivated. The errors are acknowledged with the first rising signal edge of the pulse
enable. However, the drive has still not started. A second rising signal edge is then
necessary for the release.