Connecting Cable For Encoder With Endat ® Or Ssi - Baumuller b maXX 5000 Series Instruction Handbook Manual

Mains rectifier/ active mains rectifier. axis units safety
Hide thumbs Also See for b maXX 5000 Series:
Table of Contents

Advertisement

11.1.9.3 Connecting cable for encoder with EnDat
The connecting cable is available as accessory part from Baumüller Nürnberg GmbH.
Follow the instructions below if a self-made cable is to be used:
1 Utilize the following materials:
2 Fully adjoin the cable shield with the housing of the round connector and with the
Figure 110:
NOTE
The connecting cable must be made according to the figure shown above! 
If there is a different pin assignment, the cable is not functionally operable and could
lead to defects, both in the encoder module and the encoder!
m Cable: Li9YC3x2x0.25-Li9Y3x2x0,25-Li9Y C11Y 1x2x0.34GN. Two cable pairs are
not needed and also not connected.
m High-density D-sub connector: 26-pin, male
m Round connector: 17-pin, female (e.g. from Interconnectron)
shielding of the D-sub connector.
Connecting cable for encoder with EnDat
Accessories and spare parts
®
or SSI
®
or SSI
Instruction handbook b maXX 5000
Document No.: 5.09021.16
11
255
of 328