12.6
Recommissioning
12.6 Recommissioning
Execute commissioning as with a new device, see
ZMounting–
.
292
Instruction handbook b maXX 5000
Document No.: 5.09021.16
of 328
as from page 107,
NOTICE!
Recommissioning without forming of the capacitors.
From six months storage period on, the capacitors are destroyed during commission-
ing, if they are not formed beforehand
m Reform the DC link capacitors:
n by supplying the device ready-to-operate for at least one hour with
supply voltage
n but do not transmit a pulse enable during this time.
m Consider, that it is imperative, to connect the accordingly prescribed line commu-
tating choke for this forming procedure. Devices, where no line commutating choke
is necessary can directly be supplied with mains voltage.
ZInstallation–
as from page 123.
Baumüller Nürnberg GmbH