11.4.2 Selection of the mains filter

IT systems
NOTE!
EMC limit values are not defined for transient emission in power systems without
grounded star point (IT system). A fault state (motor ground fault) can lead to the
damage of the mains filter.
It is not recommended to use mains filter in IT systems. The transient emission can
exceed the limit values of category C3.
TN systems
Based on the application, use an mains filter from the following table.
I
rated AC
at
40°C
50°C
17,5 A
16 A
32,9 A
30 A
82,2 A
75 A
100 A
100 A
142,4 A
130 A
87 A
80 A
150 A
150 A
295 A
1)
Type
BFN 3-1 - 0016 - 001
BFN 3-1 - 0030 - 001
BFN 3-1 - 0075 - 001
BFN 3-1 - 0100 - 001
BFN 3-1 - 0130 - 001
Schaffner FN 3120H-80-35
EPCOS B84143A0150R410
LGF FFU 3x295AB-SBM
With lower output at continuous operation, filters with lower rated currents can be used too. Filters with higher
rated currents are necessary in case of using the overload capacity of the mains inverters cyclically. If over-
current is only needed one-time and non-recurrently (once per hour, for a maximum of 60 s), then the filters
suggested for operation at the rated power are sufficient.
Accessories and spare parts
Part
Use with devices
number
operation at
rated power
314278
BM5031
314279
BM5032
314282
BM5043
314283
314284
BM5044
BM5173
437618
BM5174
463278
BM519X
Instruction handbook b maXX 5000
Document No.: 5.09021.16
11
Use with devices
operation at
1)
1)
cyclic overload
BM5043
271