<Sysname> reset fr inarp

reset fr pvc

Syntax
reset fr pvc interface serial interface-number [ dlci dlci-number ]
View
User view
Default level
2: System level
Parameters
interface-number: Interface number.
dlci dlci-number: Specifies the DLCI to be assigned to an FR interface, in the range 16 to 1007. DLCI 0
through 15 and 1008 through 1023 are reserved for special use and are unavailable.
Description
Use the reset fr pvc command to clear the statistics on a PVC.
Examples
# Clear PVC statistics on Serial 4/1/8:10.
<Sysname> reset fr pvc interface Serial 4/1/8:10

timer hold

Syntax
timer hold seconds
undo timer hold
View
Interface view
Default level
2: System level
Parameters
seconds: Value of T391 parameter at DTE side, which ranges from 0 to 32767 in seconds. 0 indicates
that the LMI protocol is disabled.
Description
Use the timer hold command to configure T391 parameter at the DTE side.
Use the undo timer hold command to restore the default.
By default, the parameter is 10 seconds.
The parameter is a time variable that defines the interval of Status-Enquiry message sent by DTE.
Related commands: fr lmi t392dce.