8.1.8 The TABLE function
January 2012
From the PLC main menu, press the TABLE soft key to select the table of
markers, inputs, outputs, counters, timers, bytes, words, double words, and
strings. The states are displayed dynamically on the screen.
To select a certain operand:
Use the arrow keys, or
Press the GOTO key. A dialog box appears. Enter the number of the operand
and confirm your entry with the OK soft key.
To set or reset markers, inputs, outputs, timers or counters:
Press the SET/RESET soft key.
To change bytes, words, double words or strings:
Use the arrow keys or the GOTO key to select the desired operand.
Press the ENT key and enter the new value. Conclude your entry with the
ENT key.
Soft keys within the TABLE function:
Soft key Submenu
Select Markers/Inputs/Outputs/Timers/Counters for TABLE.
8.1 PLC Functions
Function
Show a list of the markers
Show a list of the inputs
Show a list of the outputs
Show a list of the timers
Show a list of the counters
Set/reset the selected operand
Freeze the screen. Current changes to PLC
operands are no longer shown.
Return to the PLC main menu