Download Print this page

HEIDENHAIN MANUALplus 620 Technical Manual page 1527

Hide thumbs Also See for MANUALplus 620:

Advertisement

January 2012
Start
Counter is
counter
running
C39
C87
C40
C88
C41
C89
C42
C90
C43
C91
C44
C92
C45
C93
C46
C94
C47
C95
MP_run
Process marker for the timer or counter
Available from NCK software version: 597 110-03.
Format:
String
Input:
Max. 80 characters
Identifies the timer or counter (process marker), for which the
respectively configured time applies.
Timer:
Counter:
If two or more times are configured, the parameter identifies
the first timer or counter.
Default:
No entry, value optional
Access:
LEVEL3
Reaction:
NOTHING
MP_start
Start marker for the timer or counter
Available from NCK software version: 597 110-03.
Format:
String
Input:
Max. 80 characters
Identifies the start marker for the timer or counter.
Timer:
Counter:
There is no start marker for timers T96 to T999. They can be
started only through Module 9006.
This parameter is not evaluated by the control. The
PLCdesignNT development environment uses it for the
automatic generation of PLC definition files.
Default:
No entry, value optional
Access:
LEVEL3
Reaction:
NOTHING
8.4 Operands
Enable
Machine parameters
counter
C135
counter[39]
C136
counter[40]
C137
counter[41]
C138
counter[42]
C139
counter[43]
C140
counter[44]
C141
counter[45]
C142
counter[46]
C143
counter[47]
T48 to T999
C48 to C95
T0 to T47
C0 to C47
1527