1562
MP_condition
Condition for sending the strobe to the PLC
Available from NCK software version: 597 110-02.
Format:
Selection menu
Selection:
COND_ALWAYS
Strobe is output with every programmed S code
COND_ST
Strobe is output only if spindle speed changes
COND_GP
Strobe is output only if gear range changes
If the parameter is missing from the configuration, the strobe is
always output.
Default:
COND_ST
Access:
LEVEL3
Reaction:
RESET
MP_signal
Symbolic name or number of the PLC marker that is set when
the function is decoded.
Format:
String
Input:
Max. 80 characters
If you have not entered a value in the parameter
MP_acknowledge, resetting this marker means an
acknowledgment of the strobe.
No entry: The data connected with the output of the strobe is
saved without synchronization with the PLC program and the
output is immediately acknowledged.
Default:
No entry, value optional
Access:
LEVEL3
Reaction:
RESET
MP_acknowledge
Symbolic name or number of the PLC marker that is set for
acknowledging the strobe.
Available from NCK software version: 597 110-02.
Format:
String
Input:
Max. 80 characters
No entry: The strobe is reset with the PLC marker entered in
MP_signal.
Default:
No entry, value optional
Access:
LEVEL3
Reaction:
RESET