Download Print this page

HEIDENHAIN MANUALplus 620 Technical Manual page 1618

Hide thumbs Also See for MANUALplus 620:

Advertisement

1618
Module 9252 Position the cursor in the PLC table editor.
The module moves the input field in the PLC table editor to a certain line and
column.
Constraints:
The PLC table editor must have been opened with Module 9250.
The specified field must be contained in the group of fields to be edited from
Module 9250.
The line for positioning must be defined relative to the created temporary
file, starting from line 0, meaning that it might be necessary to deduct a start
line defined with Module 9250 from the line in the original file.
Call:
PS
B/W/D/K/S<Field name>
(string number 0..3 or constant string)
PS
B/W/D/K <Line>
(relative to the temporary file)
CM
9252
Error recognition:
Marker
Value
NN_GenApiModule
0
Error (M4203)
1
NN_GenApiModule
1
ErrorCode (W1022)
3
20
28
30
Meaning
Cursor was set
Error code in NN_GenApiModuleErrorCode
(W1022)
The given line is not contained in the file
being edited.
An invalid value was transferred for the
string of the field name.
The module was called from the cyclic
program part.
No editor had been opened with Module
9250.
The given field name does not exist in the
given file.
HEIDENHAIN Technical Manual MANUALplus 620

Advertisement

loading