Download Print this page

HEIDENHAIN MANUALplus 620 Technical Manual page 1658

Hide thumbs Also See for MANUALplus 620:

Advertisement

User parameters
1658
Each of the freely definable parameters is in a subfolder (key name). The key
name also specifies the name of the machine parameter. You specify the
value of the parameter in the value subfolder.
If you do not want to copy a parameter to the PLC run-time system, the
optional machine parameter MP_ignorePlc must be inserted and set to TRUE.
MP_value
List of user parameter values
Available from NCK software version: 597 110-01.
Format:
Array
Input:
Value of the user parameter
CfgOemBool: Logical values (Boolean)
CfgOemInt: Whole numbers (integer values)
CfgOemString: User text, e.g. for OEM cycles with max. 100
characters.
CfgOemPosition: Fixed-point values (position)
Default:
No value, parameter optional
Access:
LEVEL3
Reaction:
NOTHING
MP_ignorePlc
Do not copy user parameter to the PLC run-time system
Available from NCK software version: 597 110-01.
Format:
Selection menu
Selection:
TRUE
The parameter value is not copied to the PLC run-time system
FALSE
The parameter value is copied to the PLC run-time system
Default:
No value, parameter optional
Access:
LEVEL3
Reaction:
NOTHING
You can give the machine operator access via user parameters to the machine
parameters that you define yourself, see "User Parameters" on page 365.
HEIDENHAIN Technical Manual MANUALplus 620

Advertisement