MP_minimum
Smallest permissible input value
Available from NCK software version: 597 110-01.
Format:
Numerical value
Input:
Max. 50 characters
e.g.: –99999.9999
The minimum value is considered only for the columns with
numerical values or logical values. It defines the smallest
permissible numerical input value or the text representing the
logical value FALSE. For values of the FLOAT, FEED, IFEED or
LENGTH data types, the given number of decimal places
determines the number of decimal places used for values in this
column, e.g. 0.001 means 3 decimal places.
Default:
No value, parameter optional
Access:
LEVEL3
Reaction:
NOTHING
MP_maximum
Largest permissible input value
Available from NCK software version: 597 110-01.
Format:
Numerical value
Input:
Max. 50 characters
e.g.: 99999.9999
The maximum value is considered only for the columns with
numerical values or logical values. It defines the largest
permissible numerical input value or the text representing the
logical value TRUE. For values of the FLOAT, FEED, IFEED or
LENGTH data types, the given number of decimal places
determines the number of decimal places used for values in this
column, e.g. 300.000 means 3 decimal places.
Default:
No value, parameter optional
Access:
LEVEL3
Reaction:
NOTHING
MP_charset
Number of permissible characters for columns with text
(optional)
Available from NCK software version: 597 110-01.
Format:
String
Input:
Max. 224 characters
The number of permissible characters is evaluated only for text
columns (MP_unit = TEXT). If this parameter is not defined, all
characters are allowed; otherwise, only the characters listed
here are allowed.
Default:
No value, parameter optional
Access:
LEVEL3
Reaction:
NOTHING