1792
MP_timeout
Timeout in minutes for transmission of the message to the
remote service host
Available from NCK software version: 597 110-03.
Format:
Numerical value
Input:
0 to 15 [min]
Default:
No value, parameter optional
Access:
LEVEL2
Reaction:
NOTHING
MP_serverIp
Network address or host name of the server
Available from NCK software version: 597 110-03.
Format:
String
Input:
Max. 500 characters
The data traffic of the specified server(s) is checked. The default
value is the server given in the MP_host parameter.
Default:
No value, parameter optional
Access:
LEVEL2
Reaction:
NOTHING
MP_serverIpMask
Subnet mask of the server network
Available from NCK software version: 597 110-03.
Format:
String
Input:
Max. 500 characters
Enter the subnet mask of the server as four decimal numbers
separated by periods (IP address in dotted-decimal notation).
Default:
No value, parameter optional
Access:
LEVEL2
Reaction:
NOTHING