1584
MP_mCode
Number of the M function
Available from NCK software version: 597 110-01.
Format:
Numerical value
Input:
0 to 9999
Number of the M function for which the control-dependent
function is mapped.
Default:
0
Access:
LEVEL3
Reaction:
RESET
If the GFUNCTION type is defined and MP_mOffset = TRUE, the difference
between the M functions and G functions is indicated by the entry
MP_mCode for the M strobe:
Number in M strobe < EntryMP_mOffset: M function is defined
Number in M strobe > Entry MP_mOffset: G function is defined
MP_mOffset
Transferred M code is offset
Available from NCK software version: 597 110-01.
Format:
Selection menu
Selection:
TRUE
The first numerical value transferred is used as an offset and
entered in the parameter MP_min of the associated M function.
The remaining numerical values are written to the double word
entered in MP_data.
FALSE
No offset is used. The control always issues the M function
given under MP_min. Both transferred numerical values are
written to the array of double words entered in MP_data.
Default:
FALSE
Access:
LEVEL3
Reaction:
RESET