Gear shifting
January 2012
You control the gear shifting through PLC outputs. The gear range is
determined by the MP_nominalSpeed of each gear-range parameter set. The
output of the gear range is defined in MP_condition. Use MP_gearStop to
define if the spindle speed should automatically be reduced to 0 when shifting
between gears.
Configure a separate spindle parameter set for each gear stage.
Use MP_gearCode to define a word marker, in which the gear range is
transmitted to the PLC during decoding.
Note
Use the "KeySynonym" function to create new parameter sets rapidly and
easily. (in the configuration editor under KeySynonym ->
CfgKeySynonym). Only the first parameter set must be fully defined. All
further parameters sets are "linked" to the first set (MP_relatedTo), so you
only have to describe the differing parameters. For more information,
please refer to „The KeySynonym Function" on page 377.
In the list parameter MP_gearSpeed0, enter the names of spindle
parameters sets for the operating mode 0. These parameter sets define the
gear ranges for operating mode 0 if it is selected with PLC Module 9163.
(See "Switching the operating modes" on page 1029.)
Proceed in the same manner for operating mode 1 and enter the parameter
sets in MP_gearSpeed1.
Each of the lists must be sorted in ascending order, with the smallest gear
shaft speed at the top. Gear ranges are not supported if the list is missing or
empty.
Use the CfgFeedLimits configuration datum of a parameter set to define
the minimum and maximum spindle shaft speed for each gear range.
Use the parameter MP_nominalSpeed (CfgFeedLimits) to define the
rated speed for each gear range.
For digitally controlled spindles:
Use the parameter MP_gearShiftSpeed to define the gear shifting speed
for each gear range.
For analog controlled spindles:
Use the optional parameter MP_gearShiftVoltage to define for each gear
range the nominal-voltage output for gear shifting.