Download Print this page

HEIDENHAIN MANUALplus 620 Technical Manual page 1528

Hide thumbs Also See for MANUALplus 620:

Advertisement

1528
MP_gate
Release marker for counters
Available from NCK software version: 597 110-03.
Format:
String
Input:
Max. 80 characters
Only for counters:
Identifies the enabling marker (gate marker) for the
corresponding counter.
Gate markers are C96 to C143.
This parameter is not evaluated by the control. The
PLCdesignNT development environment uses it for the
automatic generation of PLC definition files.
Default:
No entry, value optional
Access:
LEVEL3
Reaction:
NOTHING
MP_unit
Time unit for timers and counters
Available from NCK software version: 597 110-01.
Format:
Selection menu
Selection:
SECONDS
Input in seconds
PLC_CYCLES
Input in number of PLC cycles
Default:
SECONDS
Access:
LEVEL3
Reaction:
NOTHING
MP_value
Default values for PLC timers and counters
Available from NCK software version: 597 110-01.
Format:
Array [1...99]
Input:
Minimum value:
Maximum value:
Decimal places:
Default:
0
Access:
LEVEL3
Reaction:
NOTHING
0
1000 000
3
HEIDENHAIN Technical Manual MANUALplus 620

Advertisement

loading