8.10 Python Settings (Option 46)
January 2012
Under System/PLC/PythonSettings you define general settings for software
option 46 "Python OEM Process."
Settings in the configuration editor
System
PLC
PythonSettings
Process
CfgPythonScript
System
Paths
CfgPlcPath
pythonScripts
Using CfgPythonScript you can specify a Python script that is to be started
automatically during start-up of the MANUALplus 620. In this case, a PLC
module call for starting the Python script is not required. The specified script
is started automatically when the Power Interrupted message is
acknowledged.
Proceed as follows to have a Python script started automatically during start-
up:
Place the cursor on CfgPythonScript and press the INSERT soft key.
Enter a key name for the script (freely selectable) and specify the *.CFG
storage file.
In MP_path, MP_jobName, MP_parameter and MP_memLimit, define
the settings for calling the Python script.
For the script to be started automatically during start-up, the key name
defined in CfgPythonScript must be entered under System/Paths/
CfgPlcPath/pythonScripts, see "MP_pythonScripts" on page 1545.
8.10 Python Settings (Option 46)
[Key name of the Python script]
path
jobName
parameter
memLimit
MP number
118303
118304
118301
118302
102315
1585