Download Print this page

HEIDENHAIN MANUALplus 620 Technical Manual page 1565

Hide thumbs Also See for MANUALplus 620:

Advertisement

January 2012
MP_singular
Function is output in a separate strobe
Format:
Selection menu
Selection:
Use the parameter MP_singular to prevent the function from
being output in a strobe together with other functions.
If several M, S, T functions are programmed in an NC block, the
strobes can be set in parallel by the NC. With this parameter,
you can exclude the current function from this parallel collection
and simultaneous transmission in one strobe.
TRUE
Function is output in a separate strobe. Combined output is
prevented.
FALSE
Function can be combined with other functions
Default:
TRUE
Access:
LEVEL3
Reaction:
RESET
MP_revoke
Numbers of functions whose effect will be canceled by the
output of the strobe.
Available from NCK software version: 597 110-02.
Format:
Array [0...19]
Input:
0 to 9999
In the list, enter the numbers of the functions whose effect will
be canceled when this code is output.
Example – Configuration of function M5: Calling function M5
cancels the effect of functions M3 and M4. In this example, you
would enter the key names of the functions M3 and M4.
The parameter is effective for updating the status of the
function in the status display and during block scan.
Note:
S outputs for the same spindle as well as T outputs and T2
outputs always cancel each other. However, in some cases
they may also cancel other M functions. M functions cannot
cancel the effects of S, T and T2 outputs.
If specific codes cancel each other, they cannot be combined in
a strobe.
Default:
No entry, value optional
Access:
LEVEL3
Reaction:
RESET
Parameter MP_blockSearch is used to define the behavior of the S function
during block scan:
8.7 S Function (S Strobe)
1565

Advertisement

loading