8.9.2 Configuration of alias functions
January 2012
Settings in the configuration editor
System
PLC
CfgPlcStrobeAlias
[Key name of alias strobe]
type
mCode
mOffset
You define data exchange between the NC and the PLC in the parameter
object CfgPlcStrobeAlias. The organization of this data exchange varies
depending on the control and is described in more detail in the Chapter „Data
Transfer NC => PLC, PLC => NC" on page 1654.
MP_type specifies the type of call. In MP_mCode, you specify the M function
on which the alias function is to be mapped.
MP_type
Type of alias function
Available from NCK software version: 597 110-01.
Format:
Selection menu
Selection:
FN19 (not with MANUALplus 620)
Two values are transmitted synchronously from the NC
program to the PLC.
FN29 (not with MANUALplus 620)
Up to eight values are transmitted asynchronously from the NC
program to the PLC.
CYCLE13 (not with MANUALplus 620)
Define spindle position for M19
TCHPROBE
Call measuring cycles
GFUNCTION
G functions are transmitted to the PLC. The G functions,
including the function parameters, are transferred in an M
strobe.
Default:
FN19
Access:
LEVEL3
Reaction:
RESET
8.9 Alias Functions (Alias Strobe)
MP number
104201
104202
104203
1583