8.7.2 Configuration of S function
Transfer and
acknowledgment of
S function
January 2012
Settings in the configuration editor
System
PLC
CfgPlcSStrobe
[Key name of S strobe]
type
condition
signal
acknowledge
spindleSpeed
badSpeed
cuttingSpeed
spindleMode
gearCode
gearSpeed0
gearSpeed1
gearStop
sCode
revoke
singular
blockSearch
sync
syncGear
Use parameter MP_condition to define the conditions for the output of the S
strobe.
There are two possibilities for transferring the S strobe to the PLC and for
acknowledgment by the PLC:
Transfer and acknowledgment with MP_signal
• Transfer of the S strobe: The PLC marker defined in MP_signal is set.
• Acknowledgment of the S strobe: The PLC marker defined in
MP_signal is reset.
Transfer with MP_signal and acknowledgment with MP_acknowledge:
• Transfer of the S strobe: The PLC marker defined in MP_signal is set.
• Acknowledgment of the S strobe: The PLC marker defined in
MP_acknowledge is set.
HEIDENHAIN recommends that you only use MP_signal for transfer and
acknowledgment.
If MP_signal and MP_acknowledge are not defined, the data of the S strobe
is saved without synchronization with the PLC program. The output is
immediately acknowledged.