Download Print this page

HEIDENHAIN MANUALplus 620 Technical Manual page 1600

Hide thumbs Also See for MANUALplus 620:

Advertisement

1600
Select MP_lockValue (optional);
If the value entered in the column equals the value given here, the text in
MP_text is displayed. It can no longer be edited. This way editing can be
disabled depending on the value.
Select MP_value (optional); enter the value for MP_dialog.
Select MP_dialog (optional);
(MP_dialogRes in preparation);
Select MP_text (optional); enter the text for MP_value.
(keep MP_width in mind)
Select CfgColumnText; enter the dialog text for the columns.
Carry out the above procedure for all new columns, and save the information
with the SAVE soft key.
The following machine parameters are used for defining the columns.
MP_width
Column width
Available from NCK software version: 597 110-01.
Format:
Numerical value
Input:
2 to 50 (column width of max. 50 characters)
Default:
2
Access:
LEVEL3
Reaction:
NOTHING
HEIDENHAIN Technical Manual MANUALplus 620

Advertisement