Safe status
Signal
bit
10
–PF.PS.AC
11
–PF.PS.DC
12
–PF.BOARD
13
–N0
14
–REQ.SS2
15
The following additional status bits are available for an external PL:
Safe status
Signal
bit
16
–SPL.A.WD
17
–SPL.B.WD
18
PGOOD.NC
19
PGOOD.PLC
20
–INT
21..31
1
The following additional status bits are available for an external MB machine
operating panel:
Safe status
Signal
bit
16
–SMOP.A.WD
17
–SMOP.B.WD
18
PGOOD.A
19
PGOOD.B
20
1
21..31
1
8.1 PLC Functions
Meaning
Power supply of inverter too low
(parameterized LIFT OFF function in some
cases).
DC-link voltage U
too low
Z
(CC: SS1)
Error in the supply voltage of the
respective module (SS1F)
Internal safe status bit
(CC: SS1)
Alarm (SS2)
Reserved
Meaning
SPL watchdog, channel A
Only in controls with functional safety (FS):
SPL watchdog, channel B
Voltage monitoring of NC reports a fault
Voltage monitoring of PLC reports an error
Internal interrupt
Reserved
Meaning
SMOP watchdog, channel A
Only in controls with functional safety:
SMOP watchdog, channel B
Voltage monitoring of channel A reports a
fault
Voltage monitoring of channel B reports a
fault
Reserved
Reserved