Execution at the
beginning or end of
block
Output of M code
during block scan
1554
In MP_singular, M codes to be output in a separate strobe are defined.
MP_singular
Function is output in a separate strobe
Format:
Selection menu
Selection:
Use the parameter MP_singular to prevent the function from
being output in a strobe together with other functions.
If several M, S, T functions are programmed in an NC block, the
strobes can be set in parallel by the NC. With this parameter,
you can exclude the current function from this parallel collection
and simultaneous transmission in one strobe.
TRUE
Function is output in a separate strobe. Combined output is
prevented.
FALSE
Function can be combined with other functions
Default:
TRUE
Access:
LEVEL3
Reaction:
RESET
In MP_blockEnd, you define whether the M function is to be executed at the
beginning or end of block.
MP_blockEnd
Function output at block end
Format:
Selection menu
Selection:
TRUE
Function is executed at block end.
FALSE
Function is executed at beginning of block.
Default:
FALSE
Access:
LEVEL3
Reaction:
RESET
Use the parameter MP_blockSearch to define whether the M code should
also be output during the block scan.
MP_blockSearch
Function output also during block scan
Available from NCK software version: 597 110-02.
Format:
Selection menu
Selection:
TRUE
Function is also output during the block scan.
FALSE
Function is not output during the block scan. The function is
collected and restored.
Default:
FALSE
Access:
LEVEL3
Reaction:
RESET