8.5 Data Organization
8.5.1 Data organization on the CFR memory card
TNC partition
PLC partition
SYS partition
Size of the
partitions
1534
The CFR memory card of the MANUALplus 620 is divided into three partitions:
User-specific data such as NC programs, tool tables, and datum tables.
Your OEM-specific data such as system files, PLC programs, machine
parameters, help files, PLC dialogs, PLC error tables, compensation value
tables and OEM cycles. The PLC partition is visible only after you have entered
the code number 807667.
As a machine tool builder, you are concerned primarily with the PLC partition.
Note
Define all your machine-specific settings with the configuration editor!
For HEIDENHAIN
System-specific files, such as system files, NC dialogs, HEIDENHAIN cycles,
etc.
The partition SYS can neither be viewed nor selected.
Warning
Alterations to the system partition can impair proper function of the control!
The storage capacity of the CFR memory card is 1 GB.
Partition
Contents
SYS:
System files
PLC:
OEM files
TNC:
User files
Size
640 MB
50 MB
300 MB