Display of symbolic
operands in the
WATCH LIST
Display of operands
in the WATCH LIST
Internal process of
the WATCH LIST
function
1492
Press the WATCH LIST soft key to call the menu of the WATCH LIST function.
Press the SYMBOL LIST soft key to open a list box containing all global and
local operands used in the PLC program.
Use the arrow keys to move within the SYMBOL LIST. Press the right arrow
key to open a tree structure. Press the left arrow key to close an open tree
structure.
Use the arrow keys to select the desired operand and press the SELECT soft
key to transfer it.
Press the INSERT soft key to insert the selected operand.
Note
Operands can only be selected with the SYMBOL LIST soft key if you are
working with the *.SRC source files of the PLC program on the control.
Otherwise the error message Selection list is empty appears.
Press the WATCH LIST soft key to call the menu of the WATCH LIST function.
Press the INSERT LINE soft key.
The following dialog box appears:
Enter the symbolic operand name in the Symbol input box, or enter the
module name in the Module input box. Press the GOTO key to view a history
list of the operand and module names last entered.
Confirm your entry with the OK soft key or button.
If you are working with the source files (*.SRC), the control internally creates
a complete symbol list from the *.MAP file, identifying the structures and
arrays. In another step, the control resolves the structure elements and array
elements, removes the nesting levels and internally creates a new list file. The
generated information is displayed in a tree structure (SYMBOL LIST
function). When you select and then insert symbols the first time, the file
PLC:\TABLE\TMP.WLT is automatically created. This file is automatically
saved when you exit the WATCH LIST function and loaded when you call the
WATCH LIST again. You can save the active WATCH LIST under any desired
name and then reload it. The control remembers the last active WATCH LIST
and automatically loads it when you call the function again.