Module 9112 Transmit ASCII characters via data interface
You must first assign the interface to the PLC and initialize it with Module
9100. Module 9112 transmits a single ASCII character.
Can only be called in a submit job or spawn job!
Call:
PS
B/W/D/K <>Interface>
0: RS232
1: RS422
PS
W/D/K
<>ASCII code [0 to 255]>
CM
9112
Error recognition:
Marker
Value
NN_GenApiModule
0
Error (M4203)
1
NN_GenApiModule
1
ErrorCode (W1022)
13
14
15
20
9.11 Data Transfer by PLC
Meaning
Character was transmitted
Error code in NN_GenApiModuleErrorCode
(W1022)
Incorrect interface
Interface not ready or no connection
Interface not assigned
Transmit buffer not empty
Module was not called in a spawn job or
submit job
1805