1602
MP_initial
Value automatically entered in a column when a new table is
created (optional).
Available from NCK software version: 597 110-01.
Format:
String
Input:
Max. 50 characters
NULL: No default value. This column may be left blank.
Value: Default value. When a new row is inserted, this value is
assigned as a default to the column.
If a default value other than NULL is given, then a valid value
must always be entered in the column.
Default:
No value, parameter optional
Access:
LEVEL3
Reaction:
NOTHING
With MP_minimum and MP_maximum you define the permissible input
ranges for the table column. Depending on the unit of measure selected in
MP_unit, the following maximum input values are permitted:
Unit of
Limit value
measure
MP_minimum
MP_unit
INT
–2147483647
BIN
%00000000
DEC
0
INDEX
0
HEX
$0
LENGTH
–999999999
FEED
–999999999
IFEED
–999999999
FLOAT
–999999999
FEED_CUT
–999999999
FEED_ROT
–999999999
Note
The input range is additionally limited by the actual (or configured) column
width (MP_width).
Limit value
MP_maximum
+2147483646
%11111111
999999999
999999999
$FFFFFFFF
+999999999
+999999999
+999999999
+999999999
+999999999
+999999999
HEIDENHAIN Technical Manual MANUALplus 620
Remark
If no input range is
configured, the following
range applies:
–999999999 to
+999999999