HEIDENHAIN MANUALplus 620 Technical Manual page 1543

Hide thumbs Also See for MANUALplus 620:

Advertisement

January 2012
MP_mainPgm
Path and file name of the PLC main program
Format:
String
Input:
Max. 260 characters
Path and file name of the PLC main program
Example: %OEM%\PLC\main.src
Default:
Access:
LEVEL3
Reaction:
NOTHING
MP_pwmPgm
Path and file name of the PLC commissioning program
Format:
String
Input:
File name and path of the PLC program for commissioning the
current controller. This PLC program is compiled and used as an
alternative if the machine parameter
MP_currentControlAdjust (System/CfgHardware) is set to
"on."
Example: %OEM%\PLC\SetUp.plc
Default:
Access:
LEVEL3
Reaction:
NOTHING
MP_errorTable
Path and file name of the PET table
Format:
String
Input:
Max. 260 characters
Path and file name of the PLC error table
Example: %OEM%\PLC\LANGUAGE\ERR_TAB.PET
Default:
Access:
LEVEL3
Reaction:
NOTHING
MP_errorText
Name of the text file for PLC error texts
Format:
String
Input:
Max. 260 characters
Name (without path) of the text file for PLC error texts.
The language-sensitive text files must be saved in
language-specific directories that cannot be changed.
Example: ErrorText.csv
Default:
Access:
LEVEL3
Reaction:
NOTHING
8.5 Data Organization