JSON
9.2.4
Services
smtp.json
GET services/smtp.json
Password is not returned when retrieving the settings.
Name
server
user
[
{ "server": "192.168.0.55"},
{ "user": "test"}
]
Set:
Form data:
[
[server=192.168.0.56]&[user=test2]&[password=secret],
]
9.2.5
Hex Format Explained
The metadata max, min, and default fields and the ADI values are ASCII hex encoded binary data.
If the data type is an integer, the endianness used is determined by the dataformat field found in
adi/info.json.
Examples:
The value 5 encoded as a UINT16, with dataformat = 0 (little endian):
0500
The character array "ABC" encoded as CHAR[3] (dataformat is not relevant for CHAR):
414243
Anybus CompactCom 40 EtherNet/IP IIoT Network Guide
Data Type
Note
String
IP address or name of mail server, e.g. "mail.hms.se"
-
String
71 (244)