Host Application Objects
Command Details: Start_Pause
Details
Command Code
Valid for:
Description
This command is sent to the host application when the system wants to initialize a pause of the system. The
length of the pause is specified in milliseconds. The response of the message contains the destination mode (i.
e. the instance number of the selected energy saving mode).
Command Details
Contents
Field
Data[0]
Pause time (low word, low byte)
Data[1]
Pause time (low word, high byte)
Data[2]
Pause time (high word, low byte)
Data[3]
Pause time (high word, high byte)
Response Details
Contents
Field
Data[0]
Instance number (low byte)
Data[1]
Instance number (low byte)
If the application is unable to select a state, given the requested pause time, it shall return one of the
error codes in the table below.
#
Error code
0x0D
Invalid state
0x12
Value too low
Anybus CompactCom 40 EtherNet/IP IIoT Network Guide
10h
Object
Description
Given the state of the device and the requested pause time it is currently not possible
to enter any energy saving mode
The requested pause time is too short