Host Application Objects
Command Details: End_Pause
Details
Command Code
Valid for:
Description
This command is sent to the host application when the system wants to return the system from a pause mode
back to "Ready to operate" mode. In the response message the number of milliseconds to actualize the switch
is returned.
Command Details
(none)
Response Details
Field
Contents
Data[0]
Time To Operate (low word, low byte)
Data[1]
Time To Operate (low word, high byte)
Data[2]
Time To Operate (high word, low byte)
Data[3]
Time To Operate (high word, high byte)
If the application is unable to end the pause it shall return the error code in the table below.
#
Error code
0x0D
Invalid state
Anybus CompactCom 40 EtherNet/IP IIoT Network Guide
11h
Object
Description
Given the state of the device, it is currently not possible to end the pause
Comments
Time needed to switch to "Ready to operate"