Anybus Module Objects
Command Details: Create
Category
Extended
Details
Command Code
Valid for:
Description
This command creates a socket.
This command is only allowed in WAIT_PROCESS, IDLE and PROCESS_ACTIVE states.
Command Details
Contents
Field
CmdExt[0]
(reserved, set to zero)
CmdExt[1]
Value:
00h
01h
02h
03h
Response Details
Field
Contents
Data[0]
Instance number (low)
Data[1]
Instance number (high)
Anybus CompactCom 40 EtherNet/IP IIoT Network Guide
03h
Object Instance
Socket Type:
SOCK_STREAM, NON-BLOCKING (TCP)
SOCK_STREAM, BLOCKING (TCP)
SOCK_DGRAM, NON-BLOCKING (UDP)
SOCK_DGRAM, BLOCKING (UDP)
Comments
Instance number of the created socket.
149 (244)