Host Application Objects
Instance Attributes (Instance #1 - #8)
#
Name
1
ModeAttributes
2
TimeMinPause
3
TimeToPause
4
TimeToOperate
5
TimeMinLengthOfStay
6
TimeMaxLengthOfStay
7
ModePowerConsump-
tion
8
EnergyConsumptionTo-
Pause
9
EnergyConsumption-
ToOperate
10
Availability
11
Power Consumption
Anybus CompactCom 40 EtherNet/IP IIoT Network Guide
Access
Data Type
Description
Get
BITS16
Bit 0:
0:
1:
Bit 1-15:
Get
UINT32
Minimum pause time in milliseconds. (t
If the value is infinite, or unknown, the maximum value 0xFFFFFFFF
shall be used.
Get
UINT32
Maximum time to go to this Energy saving mode.(ms, t
If the value is infinite, or unknown, the maximum value 0xFFFFFFFF
shall be used.
Get
UINT32
Maximum time needed to go to the "Ready to operate" mode. (ms,
t
If the value is infinite, or unknown, the maximum value 0xFFFFFFFF
shall be used.
Get
UINT32
The minimum time that the device must stay in this mode. In
milliseconds.(ms, t
If the value is infinite, or unknown, the maximum value 0xFFFFFFFF
shall be used.
Get
UINT32
Maximum time that is allowed to stay in this mode. In milliseconds.
If no maximum value is available or if not implemented, the maximum
value FFFFFFFFh shall be used.
Get
FLOAT
Amount of power consumed in this mode. (kW)
If the value is undefined the value 0.0 shall be used.
Get
FLOAT
Amount of energy required to go to this mode. (kWh)
If the value is undefined the value 0.0 shall be used.
Get
FLOAT
Amount of energy required to go to the "Ready to operate" mode
from this mode. (kWh)
If the value is undefined the value 0.0 shall be used.
Get
BOOL
Indicates if this energy saving mode is available given the current
device state.
Not used for PROFINET.
False
True
Get
UINT32
Indicates the power consumption of the device when in this state.
Not used for PROFINET.
Meaning:
Only static time and energy values are available
(Value of bit 0 attribute is not implemented)
Dynamic time and energy values are available
Reserved
)
on
)
off_min
Not available
Available (Value if attribute not implemented)
196 (244)
)
pause
)
off
SCM-1202–069 1.9 en-US