Server Side Include (SSI)
8.3.4
SsiOutput()
This command temporarily modifies the SSI output of the following command function.
Syntax:
<?--#exec cmd_argument='SsiOutput("success", "failure")'-->
success:
failure:
Default Output
(this command produces no output on its own)
Example
The following example illustrates how to use this command.
<?--#exec cmd_argument='SsiOutput ("Parameter stored", "Error")'-->
<?--#exec cmd_argument='SetConfigItem("File.cfg", Overwrite)'-->
See also...
SSI Output Configuration, p. 52
8.3.5
DisplayRemoteUser
This command stores returns the username on an authentication session.
This command cannot be used in e-mail messages.
Syntax:
<?--#exec cmd_argument='DisplayRemoteUser'-->
Default Output
Scenario
Success
Anybus CompactCom 40 EtherNet/IP IIoT Network Guide
String to use in case of success
String to use in case of failure
Default Output
(current user)