Download Print this page

Anybus CompactCom 40 Network Manual page 160

Ethernet/ip iiot
Hide thumbs Also See for CompactCom 40:

Advertisement

Anybus Module Objects
Command Details: Send_To
Category
Extended
Details
Command Code
Valid for:
Description
This command sends data to a specified host on an unconnected SOCK-DGRAM-socket. Message segmentation
may be used to send up to 1472 bytes (For more information, see appendix For more information, see
Message Segmentation, p.
Command Details
To allow larger amount of data (i.e. >255 bytes) to be sent, the command data may be segmented (For
more information, see
Contents
Field
CmdExt[0]
(reserved)
CmdExt[1]
Segmentation Control
Data[0]
Host IP address byte 4
Data[1]
Host IP address byte 3
Data[2]
Host IP address byte 2
Data[3]
Host IP address byte 1
Data[4]
Host port number (low byte)
Data[5]
Host port number (high byte)
Data[6...n]
Data to send
Response Details
Contents
Field
CmdExt[0]
(reserved)
CmdExt[1]
Data[0]
Number of sent bytes (low byte)
Data[1]
Number of sent bytes (high byte)
Anybus CompactCom 40 EtherNet/IP IIoT Network Guide
18h
Instance
162).
Message Segmentation, p.
162).
Comments
(set to zero)
For more information, see
The host address/port information shall only be included in
the first segment. All data thereafter must start at Data[0]
Comments
(ignore)
Only valid in the last segment
158 (244)
Message Segmentation, p. 162
SCM-1202–069 1.9 en-US