WEG CFW-11 Programming Manual page 70

Hide thumbs Also See for CFW-11:
Table of Contents

Advertisement

Inverter Model and Accessories Identification
P0295 – ND/HD VfD Rated current
Adjustable
Range:
6
Proprieties:
Access groups
via HMI:
Description:
This parameter presents the inverter rated current for the normal overload regimen (ND) and for the heavy overload
regimen (HD). The inverter operation mode, if it is ND or HD, is defined by the content of P0298.
6-6
0 = 3.6 A / 3.6 A
1 = 5 A / 5 A
2 = 6 A / 5 A
3 = 7 A / 5.5 A
4 = 7 A / 7 A
5 = 10 A / 8 A
6 = 10 A / 10 A
7 = 13 A / 11 A
8 = 13.5 A / 11 A
9 = 16 A / 13 A
10 = 17 A / 13.5 A
11 = 24 A / 19 A
12 = 24 A / 20 A
13 = 28 A / 24 A
14 = 31 A / 25 A
15 = 33.5 A / 28 A
16 = 38 A / 33 A
17 = 45 A / 36 A
18 = 45 A / 38 A
19 = 54 A / 45 A
20 = 58.5 A / 47 A
21 = 70 A / 56 A
22 = 70.5 A / 61 A
23 = 86 A / 70 A
24 = 88 A / 73 A
25 = 105 A / 86 A
26 = 427 A / 340 A
27 = 470 A / 418 A
28 = 811 A / 646 A
29 = 893 A / 794 A
30 = 1217 A / 969 A
31 = 1340 A / 1191 A
32 = 1622 A / 1292 A
33 = 1786 A / 1600 A
34 = 2028 A / 1615 A
35 = 2232 A / 1985 A
36 = 2 A / 2 A
37 = 527 A / 527 A
38 = 1000 A / 1000 A
39 = 1500 A / 1500 A
40 = 2000 A / 2000 A
41 = 2500 A / 2500 A
42 = 600 A / 515 A
43 = 1140 A / 979 A
44 = 1710 A / 1468 A
45 = 2280 A / 1957 A
46 = 2850 A / 2446 A
47 = 105 A / 88 A
48 = 142 A / 115 A
49 = 180 A / 142 A
50 = 211 A / 180 A
RO
01 PARAMETER GROUPS
42 Inverter Data
Factory
Setting:

Advertisement

Table of Contents
loading

Table of Contents