In order to facilitate the visualization of the main reading variables of the inverter, the group [09] - "Read Only
Parameters" can be accessed directly.
It is important to point out that all the parameters of that group can only be visualized on the keypad (HMI)
display, and that they do not allow changes by the user.
P0001 – Speed Reference
Adjustable
0 to 18000 rpm
Range:
Proprieties:
RO
Access groups
09 READ ONLY PARAMETERS
via HMI:
Description:
This parameter presents, regardless of the origin source, the value of the speed reference in rpm (factory setting).
The indication unit can be modified from rpm to another unit through P0209, P0210 and P0211, as well as the
scale by means of P0208 and P0212.
It is also possible to change the speed reference (P0121) through this parameter, when P0221 or P0222=0.
P0002 – Motor Speed
Adjustable
0 to 18000 rpm
Range:
Proprieties:
RO
Access groups
09 READ ONLY PARAMETERS
via HMI:
Description:
This parameter indicates the motor actual speed value in rpm (factory setting), with a 0.5 second filter.
The indication unit can be modified from rpm to another unit through P0209, P0210 and P0211, as well as the
scale by means of P0208 and P0212.
It is also possible to change the speed reference (P0121) through this parameter, when P0221 or P0222=0
Read Only Parameters [09]