WEG CFW-11 Programming Manual page 37

Hide thumbs Also See for CFW-11:
Table of Contents

Advertisement

Fault/Alarm
F334:
Overtemperature fault measured with the temperature
Overtemperature at IGBT
sensor (NTC) of the book 4 W phase IGBT
W B4
A336:
High temperature alarm measured with the
High Temperature at IGBT
temperature sensor (NTC) of the book 5 U phase
U B5
IGBT
F337:
Overtemperature fault measured with the temperature
Overtemperature at IGBT
sensor (NTC) of the book 5 U phase IGBT
U B5
A339:
High temperature alarm measured with the
High Temperature at IGBT
temperature sensor (NTC) of the book 5 V phase
V B5
IGBT
F340:
Overtemperature fault measured with the temperature
Overtemperature at IGBT
sensor (NTC) of the book 5 V phase IGBT
V B5
A342:
High temperature alarm measured with the
High Temperature at IGBT
temperature sensor (NTC) of the book 5 W phase
W B5
IGBT
F343:
Overtemperature fault measured with the temperature
Overtemperature at IGBT
sensor (NTC) of the book 5 W phase IGBT
W B5
A345:
Overload alarm at book 1 U phase IGBT
High Load at IGBT U B1
F346:
Overload fault at book 1 U phase IGBT
Overload at IGBT U B1
A348:
Overload alarm at book 1 V phase IGBT
High Load at IGBT V B1
F349:
Overload fault at book 1 V phase IGBT
Overload at IGBT V B1
A351:
Overload alarm at book 1 W phase IGBT
High Load at IGBT W B1
F352:
Overload fault at book 1 W phase IGBT
Overload at IGBT W B1
A354:
Overload alarm at book 2 U phase IGBT
High Load at IGBT U B2
F355:
Overload fault at book 2 U phase IGBT
Overload at IGBT U B2
A357:
Overload alarm at book 2 V phase IGBT
High Load at IGBT V B2
F358:
Overload fault at book 2 V phase IGBT
Overload at IGBT V B2
A360:
Overload alarm at book 2 W phase IGBT
High Load at IGBT W B2
F361:
Overload fault at book 2 W phase IGBT
Overload at IGBT W B2
A363:
Overload alarm at book 3 U phase IGBT
High Load at IGBT U B3
F364:
Overload fault at book 3 U phase IGBT
Overload at IGBT U B3
A366:
Overload alarm at book 3 V phase IGBT
High Load at IGBT V B3
F367:
Overload fault at book 3 V phase IGBT
Overload at IGBT V B3
A369:
Overload alarm at book 3 W phase IGBT
High Load at IGBT W B3
F370:
Overload fault at book 3 W phase IGBT
Overload at IGBT W B3
Quick Parameter Reference, Faults and Alarms
Description
Possible Causes
High ambient temperature (>45°C) and high output
current.
Blocked or defective fan.
Fins of the book heatsink too dirty, impairing the air flow.
High current at the inverter output (see figure 8.1).
0
0-31

Advertisement

Table of Contents
loading

Table of Contents