WEG CFW-11 Programming Manual page 133

Hide thumbs Also See for CFW-11:
Table of Contents

Advertisement

The "Oriented Start-up" routine presents on the keypad (HMI) the main parameters in a logical sequence. The
setting of these parameters prepares the inverter for operation with the application line and motor. Verify the step
by step sequence in the figure 11.6.
The setting of the parameters presented in this operation mode results in the automatic modification of the content
of other inverter parameters and/or internal variables, as indicated in the figure 11.6. In this way one gets a stable
operation of the control circuit with adequate values to obtain the best motor performance.
During the "Oriented Start-up" routine the "Config" (Configuration) status will be indicated on the top left part of
the keypad (HMI).
Parameters related to the motor:
 Program the contents of parameters from P0398, P0400 to P0406 directly with the motor nameplate
data.
 Options for the setting of parameters P0409 to P0412:
- Automatic, with the inverter executing the self-tuning routine as selected in one of the P0408 options.
- From the motor data sheet supplied by its manufacturer. Refer to the procedure in the section 11.7.1
of this manual.
- Manually, copying the contents of the parameters from another CFW-11 inverter, which uses and identical
motor.
e) Setting of specific parameters and functions for the application: set the digital and analog inputs and
outputs, HMI keys, etc., according to the application needs.
For applications:
 That are simple, which can use the factory settings programming for the digital and analog inputs and
outputs, use the Menu "Basic Application". Refer to the section 5.2.3 of the CFW-11 User Manual.
 That require only the digital and analog inputs and outputs with programming different from the factory
settings, use the Menu "I/O Configuration".
 That need functions as Flying Start, Ride-Through, DC Braking, Dynamic Braking, etc., access and modify
those function parameters by means of the Menu "Parameter Groups".
Vector Control
11
11-31