WEG CFW-11 Programming Manual page 218

Hide thumbs Also See for CFW-11:
Table of Contents

Advertisement

Read Only Parameters [09]
Where:
N
= Motor synchronous speed;
nom
N = Motor actual speed;
T
= Motor torque current;
m
I
= Rated motor torque current.
TM
P0010 – output Power
Adjustable
Range:
Proprieties:
Access groups
via HMI:
Description:
It indicates the inverter instantaneous output power, in kilowatt (kW).
Note!
The value indicated in this parameter is calculated indirectly, and must not be used to measure the
energy consumption.
P0012 – Di8 to Di1 Status
Refer to the section 13.1.3
P0013 – Do5 to Do1 Status
Refer to the section 13.1.4
P0014 – ao1 Value
P0015 – ao2 Value
P0016 – ao3 Value
P0017 – ao4 Value
16
Refer to the section 13.1.2.
16-4
P0009 = Tm x 100 x Y
I
= P0401
TM
Y = 1 for N
N
P0190
nom
Y =
x
N
P0400
0.0 to 6553.5 kW
RO
09 READ ONLY PARAMETERS
I
TM
P0410 x P0178
2 1/2
-
2
100
P0190 x N
nom
P0400
P0190 x N
nom
for N >
P0400
Factory