WEG CFW-11 Programming Manual page 253

Hide thumbs Also See for CFW-11:
Table of Contents

Advertisement

P0532 – Process Variable engineering Unit 3
Adjustable
32 to 127
Range:
Proprieties:
Access groups
01 PARAMETER GROUPS
via HMI:
Description:
The process variable engineering unit is composed of three characters, which will be applied to the indication of
the parameters P0040 and P0041. The parameter P0530 defines the left most character, P0531 the center and
P0532 the right most.
The characters that can be chosen correspond to the ASCII code 32 to 127.
Examples:
A, B, ...,
Y,
Z,
a,
−To indicate "bar":
P0530="b" (98)
P0531="a" (97)
P0532="r" (114)
P0533 – PVx Process Variable
P0534 – PVy Process Variable
Adjustable
0.0 to 100.0 %
Range:
Proprieties:
Access groups
01 PARAMETER GROUPS
via HMI:
Description:
Those parameters are used in the functions of the digital/relay outputs, with the purpose of signalizing/alarm, and
they will indicate:
The values are in percentage of the process variable full scale:
P0535 – Wake Up Band
Adjustable
0 to 100 %
Range:
46 PID Regulator
b,
...,
y,
z,
0,
−To indicate "%":
P0530="%" (37)
P0531=" " (32)
P0532=" " (32)
46 PID Regulator
Process Variable > VPx and
Process Variable < VPy
P0040 =
1,
...,
9,
#,
$,
%,
(10)
P0529
x 100 %
P0528
PID Regulator [46]
Factory
P0531=32
Setting:
P0532=32
(,
),
*,
+,
...
Factory
P0533=90.0 %
Setting:
P0534=10.0 %
Factory
0 %
Setting:
20-13