Parameters; General Module Parameters; Table 14 Standard Parameters Of Io-Link - WAGO 2789-9080 Product Manual

Communication modules, communication module io-link
Hide thumbs Also See for 2789-9080:
Table of Contents

Advertisement

2789-9080

4.2 Parameters

4.2.1 General Module Parameters

The product uses the following default IO-Link parameters:
Index Subin
12
13
14
15
16
17
18
19
21
22
23
24
25
26
36
37
40
41
For more information on these default parameters, see:
• IO-Link Interface and System Specification Version 1.1.2 Table B.8
• IO-Link Common Profile Specification Version 1.0 Table B.1
| Version: 1.1.0
Communication Module IO-Link
Parameters
dex
0
Device Access Locks
0
Profile
Characteristic
0
PDInput Descriptor
0
PDOutput
Descriptor
0
Vendor Name
0
Vendor Text
0
Product Name
0
Product ID
0
Serial Number
0
Hardware Revision
0
Firmware Revision
0
ApplicationSpecific Tag
0
Function Tag
0
Location Tag
0
Device Status
0
Detailed Device Status
0
ProcessDataInput
0
ProcessDataOutput
Table 14: Standard parameters of IO-Link
Data Type
Daten-
länge
(Bytes)
RecordT
ArrayT of
UIntegerT16
ArrayT of
OctetStringT3
ArrayT of
OctetStringT3
StringT
StringT
StringT
StringT
StringT
StringT
StringT
StringT
StringT
StringT
UIntegerT
ArrayT of
OctetStringT3
Fieldbus Description
Description
2
Standardized Device lock-
ing functions
2
Profile characteristic
3
Reserved for Device pro-
file
3
Reserved for Device pro-
file
32
Informative
32
Additional vendor informa-
tion
32
Detailed product or type
name
32
Product or type identifica-
tion
16
Description of Device func-
tion or characteristic
5
Vendor specific serial
number
8
Vendor specific format
32
Vendor specific format
32
Tag location or tag func-
tion defined by user
32
Standardized Device lock-
ing functions
1
Contains current status of
the Device
96
32
Read last valid Process
Data from PDin channel
32
Read last valid Process
Data from PDout channel
17