Enabling The Outputs; Enabling And Disabling The Outputs - Tabor Electronics 5064 User Manual

50 / 100 / 200 ms/s four channel arbitrary waveform generator
Table of Contents

Advertisement

2074
User Manual
Enabling the
Outputs
3
4
3-12
For safety reasons, main outputs default setting is OFF. The
outputs can be turned on and off using either the hot keys, or the
Output Menu. Observe Figure 3-3 and disable or enable the main
outputs using the procedure below. The same procedure can be
used for enabling and disabling the SYNC output. The numbers on
Figure 3-3 correspond to the procedure steps in the following
description.
1. While not editing any parameter, select the channel you want to
turn on using one of the keys that are circled with the
PROGRAM label
2. Press ON/OFF to toggle main output on and off. Notice when
you turn on the output, the LED which is associated with the
programmed output is turned on as well.
Figure 3-3, Enabling and Disabling the Outputs
Alternately, the outputs can be turned on and off from the Outputs
sub menu. Use the following procedure to open the Outputs dialog
box press to toggle output state:
3. Press TOP to display the root menu
4. Press Outputs to open the Outputs dialog box as shown in
Figure 3-3
5. Use the dial or arrow keys to access the required field. Focus is
on a filed that is painted orange.
6. To edit the field press Enter. The edited field will turn white with
orange borders
7. Use the dial or arrow keys to change the field
8. Press Enter again to lock in the setting
1
2
5, 7
6, 8

Advertisement

Table of Contents
loading

Related Products for Tabor Electronics 5064

This manual is also suitable for:

10742074