Options; Identifying Installed Options; Manual Changes; Safety Considerations - Tabor Electronics 5064 User Manual

50 / 100 / 200 ms/s four channel arbitrary waveform generator
Table of Contents

Advertisement

Options

Identifying
Installed Options

Manual Changes

Safety
Considerations
1-8
The Tabor Model 2074 can be controlled from either GPIB, USB, or
LAN interfaces. The product is supplied with IVI.COM driver and
ArbConnection software. ArbConnection simulates an array of
mechanical front panels with the necessary push buttons, displays
and dials to operate the Model 2074 from a remote interface as if it
is a bench-top instrument. ArbConnection also allows on-screen
creation and editing of complex waveforms and patterns to drive the
2074 various outputs.
It is highly recommended that the user become familiar with the
2074 front panel, its basic features, functions and programming
concepts as described in this and the following chapters.
Several options are available for the 2074. These are listed below.
Note that all options are factory installed and therefore, they must
be ordered with the product.
Option 1 - 2 Meg Waveform Memory – increases the memory
1.
capacity from 1 Meg to 2 Meg. The 2 Meg waveform memory
option is not field installable and therefore, it must be ordered
with the product. Compare the option number below with the
number printed on your instrument to check if the 2 Meg
waveform memory option is installed in your equipment.
Options must be specified at the time of your purchase. If you place
an order for an option, you may interrogate the instrument if the
option is indeed installed on your unit. The Installed Options field in
the System display shows which of the options is installed in your
instrument. Information how to operate the menus and how to
access the System menu is given in Chapter 3.
Technical corrections to this manual (if any) are listed in the back of
this manual on an enclosed MANUAL CHANGES sheet.
The Model 2074 has been manufactured according to international
safety standards. The instrument meets EN61010-1 and UL1244
standards for safety of commercial electronic measuring and test
equipment for instruments with an exposed metal chassis that is
directly connected to earth via the chassis power supply cable.
Do not remove instrument covers when operating the
instrument or when the power cord is connected to the
mains.
WARNING