ArbConnection
The Control Panels
The Pulse Generator panel contains controls that select the pulse

Pulse Generator

function and adjusts the pulse parameters. The pulses are
generated digitally suing the arbitrary waveform memory and digital
computation and therefore, there are some limitations to the
minimum to maximum range that must be observed. The pulse
design limitations are given in Appendix A. The various parameters
that control the digital pulse generator features are described
below.
Figure 4-21, the Digital Pulse Generator Panel
Pulse Mode
The Pulse Mode group has controls to turn on pulse generator
functions, select of the output generates single or double pulse
shape and selects the pulse polarity from one of the Normal,
Complemented and Inverted options.
Pulse Parameters
There are two types of pulse parameters: the Shared parameters
are common to both channels so modification of one of these
parameters affects both channels simultaneously. The shared
parameters are Period, Rise Time, High Time and Fall time.
There are also other parameters that can be programmed
individually for each channel. These are: Delay, High Level and Low
level. Programming channel 1 parameters do not affect channel 2
parameters and visa versa.
To display and modify parameters, click on the and next to the
required parameter change and modify time per your requirements.
The range of each parameter is specified in Appendix A.